Can’t Find What You Are Looking For? Find Out About Our Bespoke Design Solutions.

Read More.

  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics
  • Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics

Inherent Fire Retardant Blackout Fabric Fire Resistant Window Curtain fabrics

SKU: BG-ZG-313

Fire Retardant Blackout Anti-UV GRS Soundproof
NFPA701,M1 EN13501-1,EN13773 CLASS 1,BS5867-2 TYPE C,DIN4102-B1,CANULC-S109-14,CA TITLE 19 section1237,UIC564-2,IMO
150/280/300cm
250/260/280/420gsm
Flame retardant, Blackout, Anti-uv, GRS, Soundproof, Heat and Cold Protection
100% polyester
Curtain
BS5867-Blackout fabric
Fabric Samples: We are pleased to offer complimentary A4-sized fabric samples. Customers are only responsible for the shipping charges.

Customs & Import Duties (U.S.): Due to recent changes in U.S. customs policy, orders may incur duties or taxes—even under $800. These fees are not included in the price or shipping and must be paid by the buyer.

Test Report Summary: BS5867 Test for Flame Retardancy

  • Sample Description: 100% Polyester Inherent Flame Retardant Blackout Curtain Fabric
  • Color: Royal Blue
  • Composition: 100% Polyester
  • Test Requested: Type C of BS 5867-2:2008, Specification for Fabrics for Curtains, Drapes, and Window Blinds
  • Conclusion: The tested sample meets the requirements of Type C of BS 5867-2:2008.

Test Details

  • Sample Description: Fabric (Royal Blue)
  • Area Density: 248 g/m²
  • Sample Size: 200mm x 160mm
  • Pre-Condition: T: 20±2℃, H: 65±5%, for at least 24 hours
  • Cleansing Procedure: 50 cycles of standard washing as per BS EN ISO 10528

Test Results

Procedure A (Surface Ignition) Flame Application Time:

Time (s) Direction After Flame (s) After Glow (s) Max. Vertical Extent of Hole (mm) Max. Horizontal Extent of Hole (mm)
5 Machine 0 0 67 20
15 Machine 0 0 108 36
20 Machine 0 0 100 28
30 Machine 0 0 110 32
After Cleaning Machine 0 0 55 22

 


Observations

  • Flame Reached Top/Vertical Edge: No
  • Hole Reached Top/Vertical Edge: No
  • Flaming Debris: No
  • Photo Appendix: SGS authenticated the photo on the original report.